6325 Shares

C++ problem can you solve? or do you know the link of its answer?What would you like to ask?

C++ problem can you solve? or do you know the link of its answer?What would you like to ask? Topic: Application letter address change
July 16, 2019 / By Eldreda
Question: The purpose of this assignment is to design and implement a DVD Rental Application that allows a DVD shop owner to perform regular daily operations (a detailed list of the functionality needed is provided in the next section). The following aspects in C++ will be enforced: • Handling Advanced Structures • Handling Pointers • Handling Abstract Data Types (Linked Lists are recommended) • Handling File I/O The remainder of this document will guide you through the details of the assignment. This assignment is a long one. You are advised to start with it as soon as possible. 3 Description For this application, we will assume that there are three functionalities required by the shop owner: (1) Manage Customers (2) Manage Products (3) Issue Receipts. All records created by this application will be saved in a Database. For simplicity, we will choose our database to be a plain text file. 3.1 Manage Customers Before we can start the renting process we must first allow the user to create, delete, and change status of customer records. All the records created should be saved in a file called users.dat. A customer record consists of the following: 1. ID: A unique number given to each customer 2. Name: The full customer name 3. Address: The street where the customer lives 4. Status: The current customer status All the record fields except the ID should be filled by the user whenever they wish to create a new customer record. The ID will be generated automatically by taking the first three letters from the Name and appending them to a number that represents how many times this Name has been used before (this could involve a simple search operation). Example: mat0, mat1 ... mat13. 3.2 Manage Products Now that we are able to create clients, we can move on to create DVD records. All DVD records created must be stored in a file called dvd.dat. A DVD record is comprised of the following: 1. Name: The name of the DVD 2. Price: The price of the DVD 3. Serial: The DVD serial# All the record fields must be filled by the user whenever they wish to create a new DVD record. 3.3 Manage Receipts Now that the infrastructure is implemented, we can start renting DVD disks. This can be achieved by using Receipts: every time some customer rents a DVD we issue a receipt for him/her. Every time we create a receipt record, we must store it in a file called unpayed_receipts.dat, which obviously keeps track of all the un-paid receipts. Every time we pay a receipt, that record is moved from the file unpayed_receipts.dat to payed_receipts.dat; this is meant to keep track of all issued receipts. Note 1: Deleting receipts is not a common thing to do; that is why we do not need to implement it in this program Note 2: Paying a receipt can be done in partial. So if i have a receipt with value 100$, I can pay 50$ now and 50$ later. In this case, the receipt record in the un-paid file until it is fully paid. 4 Required Functionality All the required functionality can be viewed in the sample executing of the program listed below: C:> DVDManager.exe +------------------------------------... | Welcome to the DVD Manager | | Created by: Dr. C | +------------------------------------... Main Menu: 1- Manage Customers 2- Manage DVD Disks 3- Manage Receipts 4- Exit Enter Choice > 1 Manage Customers Menu: 1- Create New Customer 2- Delete Customer 3- Update Customer Status 4- View Customer List 5- Back to Main Menu Enter Choice > 5 Main Menu: 1- Manage Customers 2- Manage DVD Disks 3- Manage Receipts 4- Exit Enter Choice > 2 Manage DVD Disks Menu: 1- Create New DVD Record 2- Delete DVD Record 3- View DVD Disk List 4- Back to Main Menu Enter Choice > 4 Main Menu: 1- Manage Customers 2- Manage DVD Disks 3- Manage Receipts 4- Exit Enter Choice > 3 Manage Receipts Menu: 1- Issue New Receipt 2- Pay a Receipt 3- View Outstanding Receipts List 4- View All Receipts List 5- Back to Main Menu Enter Choice > 5 Main Menu: 1- Manage Customers 2- Manage DVD Disks 3- Manage Receipts 4- Exit Enter Choice > 4 Thank you for using the DVD Manager, Exiting ...
Best Answer

Best Answers: C++ problem can you solve? or do you know the link of its answer?What would you like to ask?

Cherilyn Cherilyn | 10 days ago
Two things: 1) wrong section 2) this is way too long for anyone reasonable to answer. We don't want to do a programming assignment for you. If you want help, you need to narrow your question down to a more specific question (that isn't just the entire assignment).
👍 128 | 👎 10
Did you like the answer? C++ problem can you solve? or do you know the link of its answer?What would you like to ask? Share with your friends

We found more questions related to the topic: Application letter address change


Cherilyn Originally Answered: Automatic Best Answer! Just Solve Problem?
I will assume the question to be "What were the voting results?" 12 voted for all 7. 19 voted for only 1, 2, and 6 (31-12) 17 voted for only 1, 3, and 5 (29-12) 8 voted for only 2, 3, and 4 (20-12) PS- Your example is wrong 5 voted for only 3 (42-12-17-8) 10 voted for only 2 (49-12-19-8) 11 voted for only 1 (59-12-17-19)
Cherilyn Originally Answered: Automatic Best Answer! Just Solve Problem?
74 people don't like these teams (Thank God!) 1. 49ers? (59)-12-17-19=11 2. Giants? (49)-12-8-19=10 3. Warriors? (42)-12-8-17=5 4. Giants and Warriors? (20)-12=8 5. '49ers and Warriors? (29)-12=17 6. '49ers and Giants? (31)-12=19 7. All three? (12) Subtract 12 from each category 1-6 Subtract totals of 5+6 from 1 Subtract totals of 4+6 from 2 Subtract totals of 4+5 from 3 Add totals of 1+2+3 = 26 people like these teams 100-26 = 74 people don’t like these teams
Cherilyn Originally Answered: Automatic Best Answer! Just Solve Problem?
Hit . Ctrl + Alt + Delete buttons . See what variety of paying for record of classes is working could desire to be approximately 35 of them start to envision what each and each is an any you be responsive to what they are and isn't any longer mandatory to make the laptop artwork . click on them and close them down . that could desire to help out a bargain . then you fairly can bypass to . click Run enter msconfig . And the final tab on the the appropriate option click it and spot what classes are interior the commence up record of issues that could consume up reminiscence and CPU skill . Un verify those you be responsive to what they are and are not mandatory to make the laptop artwork . in case you purchased a iMac you do no longer could desire to do any of one of those stuff . Mac desktops have been given basically 3 classes working to cause them to artwork . Plus the only that the Mac person needs to run .

Ashley Ashley
This is most often the messy approach, however right here is going. Calculate the kinetic vigour (KE) of the bullet earlier than it hits the block. KE = a million/2mv^two So: KE(access) = (.five)(13g)(230 m/s)^two = 343.eighty five J Calculate the KE of the bullet after it leaves the block. KE(go out) = (.five)(13g)(a hundred and seventy m/s)^two = 187.eighty five J Subtract KE(access) from KE(go out) and you have got KE(block). KE(block) = 156 J Rearrange the equation to calculate for v(block). v = ((KE)(two/m))^a million/two v(block) = ((156 J)(two/two kg))^a million/two v(block) = 12.forty nine m/s
👍 40 | 👎 4

Ashley Originally Answered: MY AC at home has a problem and there is one good answer but it does NOT solve?
Why do you keep replacing parts when you're not sure the parts are the problem? That's an expensive way to troubleshoot, don't you think? The unit you have is a two-speed. At high speed, the unit is a 5-ton. At low speed, the unit is a 3-ton. When the two-stage thermostat calls for high speed cooling mode, the system runs until the temperature in your home gets within 2 degrees of the thermostat setpoint. At that time, the thermostat tells the unit to run in low speed cooling mode. In order for that to happen, the two-speed control (TSC) stops the compressor and condenser fan motor. After a set amount of time (60 seconds), the TSC starts the compressor in low speed mode and starts the condenser fan motor. The unit runs in low-speed until the thermostat is satisfied. The TSC is, basically, the brains of the outside unit. Not only does it tell the unit to run in high or low speed, also it monitors the compressor motor winding temperature through a sensor connected to the control. If the sensor senses the compressor motor windings get too hot, TSC shuts down the unit and waits for the motor windings to cool down. The TSC counts this as a fault. After a 5 minute delay, the TSC will tell the unit to run. If the sensor has not cooled down enough to reset, the TSC will shut down the unit again and it will go into another 5 minute delay. It tries 3 times and if the sensor has not reset during those 3 times, the TSC will lock out on 3 faults. The only way to remove the 3 faults and reset the TSC is to either turn off the thermostat for 5 seconds or kill the power to the unit. In addition to monitoring the compressor motor windings, also the TSC monitors the refrigerant pressures through the low and high pressure controls. If the high pressure control trips open, the high pressure control would need to be reset manually. The low pressure control resets itself automatically, however if the unit trips on the low pressure control during a call for cooling, the TSC sees this and counts this condition as a fault and, after 3 faults, the TSC will lock out. The low pressure control tripping is what we in the trade call "short-cycling" and usually this condition is caused due to a low refrigerant charge, but there are other possibilities, too. So, the question is why is the TSC locking out? When you can figure that out and eliminate the cause of the lock outs, your system can be repaired properly without having to keep changing out good parts that don't need changing. Good luck.
Ashley Originally Answered: MY AC at home has a problem and there is one good answer but it does NOT solve?
The potential relay is used to take the start capacitor out of the circuit once the compressor hits full speed and the voltage hits maximum. However, if nothing is running, it definitely isn't the potential relay causing this problem as this only helps the compressor start and has nothing to do with the fan motor. These units have high and low pressure cutouts, which will shut the unit off once they trip. The low pressure is an auto reset, meaning it will reset itself after a few minutes, and the unit will automatically restart. However, the high pressure cutout is a manual reset, and you have to either reset the switch (probably has a red button on top of it) or simply cut power off and back on, which you've been doing. Once you reset the breaker, this resets the pressure switch, and then the unit goes through a 5 minute delay forced by the TSC. This sounds exactly like what you described. Did this tech that came out put gauges on the system? You could have a stopped up condenser coil that is jacking up the head pressure up and tripping the high pressure cutout. BTW, here is a technical manual for that outdoor unit: http://0190acd.netsolhost.com/manuals/HS...

If you have your own answer to the question application letter address change, then you can write your own version, using the form below for an extended answer.